The reliability and validity of the Figure of 8 Walk test in older people with knee replacement

图8走(F8W)测试看着我走n straight and curved paths in both clockwise and anti-clockwise directions (Fig. 1). The time taken to carry out the test is recorded along with the number of steps and an accuracy and smoothness score. It is important to look at this to get an accurate measure of a person’s walking in everyday life. The test has been used in the elderly and those with stroke. However, it is not yet known if the test is valid and reliable for use in people who have had a knee replacement. The test has also never been used out in the community in people’s homes where conditions are likely to differ from clinics that are brightly lit and have large areas of smooth floors.

Figure of 8 Walk test set up. Arrows indicate direction of walking pattern. Atlas of Science

Fig. 1. Figure of 8 Walk test set up. Arrows indicate direction of walking pattern.

The study aimed to see if the F8W test was a valid and reliable measure for older people following knee replacement in community settings. Seventy-four people over the age of 55 took part. Half of the participants completed the test in their homes and half completed it in a physiotherapy clinic. The F8W test was completed and the time taken to complete was recorded along with number of steps and a measure for accuracy to state whether the patient stood outside of the 0.6m boundary for the test and a measure of smoothness to state whether the participant kept the same pace. Alongside this, two other measures of walking called the Timed Up and Go (TUG) and the Timed Walk Test (TWT) were carried out at the first assessment. The participants were then tested a second time a week later by two different therapists to see if they recorded similar times as a measure of reliability.

The mean age of the participants was 70.3 (SD 7.4), mean BMI was 31.3 (SD 5.4) and mean Oxford Knee Score 39.8 (SD 7.1). Participants mean time between surgery and assessment was 15 months (SD 2). The times taken to complete the F8W, TUG and TWT were similar when completed at home or at the physiotherapy clinic (Fig. 2). The difference in F8W test assessment times within the same assessor were between 1.8s and between assessors were 1.2s on 95% of occasions. The F8W and TUG times were highly correlated for the overall sample (r = 0.921) and subgroups: Home (r = 0.945) and Clinic (r = 0.911). The F8W and TWT were also highly correlated for the overall sample (r = 0.834) and subgroups, Home (r = 0.864) and Clinic (r = 0.793). The F8W test also provides a measure of accuracy and smoothness. For accuracy on 6 occasions a participant stepped outside the 0.6m boundary of the test. For smoothness 62 participants scored the maximum of 3 indicating they could complete the test with a regular pace and no hesitancy.

Outcome assessment summary. Atlas of Science

Fig. 2. Outcome assessment summary.

These results confirm that there is good validity and reliability for the F8W test in a clinical setting but also in patients’ homes following knee replacement. The F8W also showed minor walking difficulties such as stride length and pace that were not apparent with the TUG and TWT making it a more useful measure of functional performance for this population.

Martha Batting, Karen Barker
Physiotherapy Research Unit, Nuffield Orthopaedic Centre, Oxford University Hospitals Foundation Trust,
Oxford, United Kingdom

Publication

The reliability and validity of the Figure of 8 Walk test in older people with knee replacement: does the setting have an impact?
Barker KL, Batting M, Schlüssel M, Newman M
Physiotherapy. 2019 Mar

Facebook twitter linkedin mail Facebook twitter linkedin mail

Leave a Reply